The Validity & Reliability of the Danu System
for Countermovement Jumps
Introduction
Vertical jump performance, specifically Jump Height (JH), is considered a crucial functional parameter for athletic populations [1]. The Countermovement Jump (CMJ) is instrumental in assessing vertical jump capabilities as it offers insights into an athlete's stretch-shortening cycle [2] enables effective monitoring of neuromuscular fatigue [3], evaluates interlimb asymmetries [4], and identifies differences between distinct populations [5]. Traditionally, practitioners have employed force plates to assess CMJ height, which are widely regarded as the gold standard [6] [7] [8]. Recently, however, there has been a shift towards more cost-effective and practical alternatives that can be integrated into natural sporting environments, facilitated by advances in wearable technology [9]. This study aims to investigate the concurrent validity and reliability of the Danu Sports system in measuring Countermovement Jump height and flight time, comparing its performance against that of a force plate (ForceDecks Dual Force Plate System, VALD Performance PTY LTD, Queensland, Australia).
Method
Forty team sport players (21 males, 19 females) volunteered for this study. Participants were asked to perform three countermovement jumps (CMJs) while wearing Danu socks (figure 1a) and using their own footwear on Vald ForceDecks (figure 1b).
Both Flight Time and Jump Height was calculated by identifying final contact and initial contact, through custom algorithms developed to process the raw sensor data collected from the Danu socks. Jump height is derived from flight time [10] as shown in equation 1. Vald automatically outputs both flight time and jump height through their software.
A total of 117 CMJs were recorded, with 3 CMJs being missed on the Vald system. The data analysis included Intraclass Correlation Coefficient, Pearson Correlation Coefficient, Bland-Altman Analysis, Adjusted R², Mean Absolute Error (MAE), and Root Mean Square Error (RMSE), selected for their robustness in assessing measurement accuracy and agreement between the Danu system and Vald ForceDecks.
a
b
Figure 1. (a) Danu Sports Smart Sock. (b) Vald ForceDecks Force Plates.
Results
The Intraclass Correlation Coefficient (ICC) values derived from comparisons between the Danu system and the Vald force plates were consistently > 0.9 (0.96-0.97), indicating an exceptional level of agreement between the two measurement systems [11]. The results highlight the reliability and accuracy of the Danu system in replicating measurements obtained from the force plates with the Bland-Altman analysis mean difference sat at 0s for flight time and -0.02cm for jump height with no significant systematic bias, and the Pearson R2 values of 0.95 for both metrics. For a detailed breakdown of the results for each metric along with the statistical analyses conducted, refer to table 1.
Figure 2. Scatter plot comparison for flight time (s) and jump height (cm), Danu Vs. Vald
Figure 3. Bland-Altman plot for comparison between Danu and Vald for flight time (s) and jump height (cm).
Table 1. Statistical analysis outcomes.
Metric | MAE | ICC (2,1) | Pearson r | Adj. R2 | Pearson p | RMSE | Bland-Altman (Mean, upper, & lower limits) |
Flight Time | 0.01 | 0.97 | 0.98 | 0.95 | <0.001 | 0.013 | 0.00, +0.02,-0.02 |
Jump Height (cm) (n=117) | 1.34 | 0.96 | 0.98 | 0.95 | <0.001 | 1.83 | 0.02, +2.83,-2.87 |
Metric | MAE | ICC (2,1) | Pearson r | Adj. R2 | Pearson p | RMSE | Bland-Altman (Mean, upper, & lower limits) |
Flight Time | 0.01 | 0.97 | 0.98 | 0.95 | <0.001 | 0.013 | 0.00, +0.02,-0.02 |
Jump Height (cm) (n=117) | 1.34 | 0.96 | 0.98 | 0.95 | <0.001 | 1.83 | 0.02, +2.83,-2.87 |
Conclusion
The results demonstrate a strong correlation and excellent agreement between the Danu system and Vald force plates, underscoring the high validity and reliability of the Danu system in measuring biomechanical metrics comparable to those captured by the force plates, similar to previous studies conducted on wearable technology [12] [13] [9]. Therefore, the Danu system is a valid and reliable product that can be used for precise biomechanical assessments applicable in both research and clinical settings. Future independent studies could help to verify these findings.
Bibliography
[1] | M. J., S. Murphy, S. J. Rej and P. Comfort, “Countermovement-Jump-Phase Characteristics of Senior and Academy Rugby League Players.,” International Journal of Sport Physiological Performance, vol. 12, pp. 803-811, 2017. |
[2] | R. Berton, M. E. Lixandrao, C. M. Pinto and V. Tricoli, “Effects of weightlifting exercise, traditional resistance and plyometric training on countermovement jump performance: A meta-analysis.,” J. Sport. Sci., vol. 36, pp. 2038-2044, 2018. |
[3] | J. G. Claudino, J. Cronin, B. Mezencio, D. T. McMaster, M. McGuigan, V. Tricoli, A. C. Amadio and J. C. Serrao, “The countermovement jump to monitor neuromuscular status: A meta-analysis.,” J. Sci. Med. Sport., vol. 20, pp. 397-402, 2017. |
[4] | J. P. Lake, P. D. Mundy, P. Comfort and T. J. Suchomel, “Do the peak and mean force methods of assessing vertical jump force asymmetry agree?,” Sport. Biomech., vol. 19, pp. 227-234, 2020. |
[5] | Z. Anicic, D. Janicijevic, O. M. Knezevic, A. Garcia-Ramos, M. R. Petrovic, D. Cabarkapa and D. M. Mirkov, “Assessment of Countermovement Jump: What Should We Report?,” Life (Basel), vol. 13, no. 1, p. 190, 2023. |
[6] | J. J. Downling and L. Vamos, “Identification of Kinetic and Temporal Factors Related to Vertical Jump Performance.,” Journal of Applied Biomechanics, vol. 9, no. 2, pp. 95-110, 1993. |
[7] | H. Hatze, “Validity and Reliability of Methods for Testing Vertical Jumping Performance.,” Journal of Applied Biomechanics, vol. 14, no. 2, pp. 127-140, 1998. |
[8] | P. N. Linthorne, “Analysis of Standing Vertical Jumps Using a Force Platform.,” American Journal of Physics., vol. 69, no. 11, pp. 1198-1204, 2001. |
[9] | S. Marković, M. Dopsaj, S. Tomažič, A. Kos, A. Nedeljković and A. Umek, “Can IMU Provide an Accurate Vertical Jump Height Estimate?,” Appl. Sci. , vol. 11, p. 12025, 2021. |
[10] | C. Bosco, P. Luhtanen and P. V. Komi, “A simple method for measurement of mechanical power in jumping.,” Eur J Appl Physiol Occup Physiol., vol. 50, no. 2, pp. 273-82, 1983. |
[11] | T. K. Koo and M. Y. Li, “A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research.,” J Chiropr Med., vol. 15, no. 2, pp. 155-63, 2016. |
[12] | T. M. Comyns, J. Murphy and D. O'Leary, “Reliability, usefulness, and validity of field-based vertical jump measuring devices.,” J Strength Cond Res, vol. 37, no. 8, pp. 1594-1599, 2023. |
[13] | R. Fathian, A. Khandan, L. Z. Chiu and H. Rouhani, “Assessment of countermovement jump with and without arm swing using a single inertial measurement unit.,” Sports Biomech., 2022. |